Home / Applications / Industrial process water
Raw water · process water · boiler and cooling makeup
Plant water from the river, without the clarifier and sand filter.
Plants that draw river, lake or well water usually run a coagulant, a clarifier and sand filters to make process water. Every storm means re-tuning the dose and hauling more sludge. Scrub UF replaces that train with a fine screen and a flat-sheet membrane in an open tank, often without any coagulant.

The problem
Why industrial process water projects stall.
“Every storm changes our coagulant dose.”
Conventional trains dose coagulant that tracks the raw water. Scrub UF is a physical barrier that tolerates turbidity swings, often without coagulant.
“Our sand filters let turbidity through.”
Scrub UF permeate is typically below 1 NTU and often below 0.1 NTU, with SDI typically below 4, ready for RO or boiler pretreatment.
“Sludge and backwash water add up.”
No coagulant means less chemical sludge. No backwash means no backwash water to handle.
“Our RO and boiler treatment foul too often.”
A stable UF permeate protects the RO, ion exchange and cooling systems downstream.
Where Scrub UF fits
Typical trains.
| Goal | Example train |
|---|---|
| Process and wash water | Intake → fine screen → Scrub UF → plant |
| Boiler feed | Intake → fine screen → Scrub UF → RO → polishing → boiler |
| Cooling tower makeup | Intake → fine screen → Scrub UF → tower |
| Potable use at the plant | Scrub UF → disinfection, subject to state approval |
At a glance
What the membrane does.
| Item | Scrub UF (typical) |
|---|---|
| Membrane | PVDF thin-film composite flat-sheet ultrafiltration, on PET non-woven with a PP filtrate channel, about 0.04 µm nominal pore size. Same membrane family as Swing; the difference is mechanical scrubbing rather than swing/scour cleaning |
| Fouling control | Circulating scrubbing media wipes the sheets while they run. No backwash pump, tank or cycle |
| Design flux | 9–12 GFD (15–20 LMH); peak 15 GFD (25 LMH) |
| Permeate | Turbidity typically below 1 NTU, often below 0.1 NTU; SDI typically below 4 |
| Recovery | 90% or better, depending on feed and concentrate handling |
| Chemical clean | Often every few weeks to about 1–2 months on suitable feeds |
Typical values from reference installations, test data and design studies. Your proposal sets the design point and any guaranteed values for your water.
Projects like these
Reference results on similar water.
From reference installations, tests and design studies. Names and sites are withheld. Results on other water will differ, and we confirm by pilot.
Village spring water
About 26,000 gpd (100 m³/d), raw 11–40 NTU to permeate below 0.3 NTU.
River water, long-term test
Observed flux about 24–29 GFD (40–50 LMH) on clean surface water, not a design value. TMP recovered after each cleaning and drain.
Storm water to RO
Feed TSS 15–100 mg/L to filtrate below 5 mg/L, with about one-third of the solid waste of a coagulation train.
Packaged units
Sizes from 861 to 11,300 ft² (80 to 1,050 m²).
| Model | Membrane area | Design permeate* |
|---|---|---|
| Scrub-UF80 | 861 ft² (80 m²) | 5–7 gpm · 7,800–10,300 gpd (29–38 m³/d) |
| Scrub-UF260-1 | 2,800 ft² (260 m²) | 17–23 gpm · 25,200–33,600 gpd (94–125 m³/d) |
| Scrub-UF350-1 | 3,770 ft² (350 m²) | 24–31 gpm · 33,900–45,200 gpd (126–168 m³/d) |
| Scrub-UF260-2 | 5,600 ft² (520 m²) | 35–47 gpm · 50,400–67,200 gpd (187–250 m³/d) |
| Scrub-UF350-3 | 11,300 ft² (1,050 m²) | 71–94 gpm · 101,700–135,600 gpd (378–504 m³/d) |
*Design permeate at 9–12 GFD (15–20 LMH), peak 15 GFD (25 LMH). Larger plants use multiple units or a multi-cell tank, confirmed per project. Units are assembled in Poughkeepsie, NY.
Try it first: the Scrub-UF80 ships as a unit to buy or rent for a pilot on your own water. Rentals
Honest selection
What UF will and won’t do here.
Ultrafiltration removes particles, colloids and microbes. It does not soften, desalt or remove dissolved iron and manganese unless they are oxidized first. For drinking water, treatment credit widely documented in industry literature needs challenge and integrity testing, and no drinking-water certification is claimed on this page.
What to send
Water first.
- Source: river, lake, reservoir or well
- Flow, turbidity range, TSS, TOC, iron, manganese, temperature (°F)
- Uses: process, boiler, cooling, potable
- Current treatment and its problems
- Space and power
Related
UF for surface and drinking water · UF for RO pretreatment · Cooling tower blowdown reuse
We presently have a manufacturing facility in Poughkeepsie, New York, and the ability to ship from Europe and Asia.
Warranty against defects in materials and workmanship. For industrial applications, membrane life depends on the service duty, so we run a pilot test to establish expected system life.
Tell us your domestic-content requirements, including Build America, Buy America (BABA), and we'll review what we can document.
Zyramic, Inc.
14 Tucker Dr, Suite 4, Poughkeepsie, NY 12603
845-402-6318 · tom@zyramic.com