Tertiary filtration · Scrub UF

Tertiary filtration that reaches membrane-grade turbidity, without a backwash system.

Reuse permits and tighter TSS and phosphorus limits push treatment plants past sand and cloth filters to a membrane barrier. Scrub UF puts flat-sheet ultrafiltration in an open tank after the clarifier. Media scrubs the sheets while they run, so there is no backwash pump, tank or cycle.

Submerged ultrafiltration installed in a tank

The problem

Why tertiary filtration for reuse projects stall.

“Our reuse permit wants membrane-grade water.”

Some reuse rules, for example, require membrane filtrate at or below 0.2 NTU more than 95% of the time and never above 0.5 NTU, continuously monitored. Scrub UF permeate is typically below 1 NTU and often below 0.1 NTU. We do not claim state acceptance on this page.

“Backwash systems are the part that breaks.”

Pressurized and hollow-fiber UF need backwash pumps, tanks, valves and sequencing. Scrub UF has none of that.

“Coagulant dose keeps creeping up.”

Conventional tertiary trains dose coagulant that changes with the water and makes chemical sludge. Scrub UF often runs without coagulant. Phosphorus limits may still call for one.

“We need more capacity in the same footprint.”

Submerged flat sheets go into existing or new tankage, and units are added as flow grows.

Where Scrub UF fits

Typical trains.

GoalExample train
Lower TSS for reuse or dischargeFinal clarifier → Scrub UF → disinfection
Lower total phosphorusFinal clarifier → coagulant dose → Scrub UF
Reuse with a dissolved-solids specFinal clarifier → Scrub UF → NF or RO → reuse
Lower CODFinal clarifier → Scrub UF → ozone or advanced oxidation

At a glance

What the membrane does.

ItemScrub UF (typical)
MembranePVDF thin-film composite flat-sheet ultrafiltration, on PET non-woven with a PP filtrate channel, about 0.04 µm nominal pore size. Same membrane family as Swing; the difference is mechanical scrubbing rather than swing/scour cleaning
Fouling controlCirculating scrubbing media wipes the sheets while they run. No backwash pump, tank or cycle
Design flux9–12 GFD (15–20 LMH); peak 15 GFD (25 LMH)
PermeateTurbidity typically below 1 NTU, often below 0.1 NTU; SDI typically below 4
Recovery90% or better, depending on feed and concentrate handling
Chemical cleanOften every few weeks to about 1–2 months on suitable feeds

Typical values from reference installations, test data and design studies. Your proposal sets the design point and any guaranteed values for your water.

Projects like these

Reference results on similar water.

From reference installations, tests and design studies. Names and sites are withheld. Results on other water will differ, and we confirm by pilot.

Design study, low-solids process water

One engineering design study, about 264,000 gpd (1,000 m³/d) of pretreated low-solids industrial water: specific energy about 0.5 kWh/kgal (0.13 kWh/m³) for Scrub UF versus about 1.4 kWh/kgal (0.36 kWh/m³) for pressurized UF. Not a guarantee. Chemical cleaning about every 1–2 months versus about every 7 days in that study.

Storm water to RO

Feed TSS 15–100 mg/L, filtrate below 5 mg/L, with about one-third of the solid waste of a coagulation train.

Hollow-fiber comparison

Reference data: Scrub tolerated about 200 mg/L feed TSS vs about 100 mg/L for submerged hollow fiber.

Packaged units

Sizes from 861 to 11,300 ft² (80 to 1,050 m²).

ModelMembrane areaDesign permeate*
Scrub-UF80861 ft² (80 m²)5–7 gpm · 7,800–10,300 gpd (29–38 m³/d)
Scrub-UF260-12,800 ft² (260 m²)17–23 gpm · 25,200–33,600 gpd (94–125 m³/d)
Scrub-UF350-13,770 ft² (350 m²)24–31 gpm · 33,900–45,200 gpd (126–168 m³/d)
Scrub-UF260-25,600 ft² (520 m²)35–47 gpm · 50,400–67,200 gpd (187–250 m³/d)
Scrub-UF350-311,300 ft² (1,050 m²)71–94 gpm · 101,700–135,600 gpd (378–504 m³/d)

*Design permeate at 9–12 GFD (15–20 LMH), peak 15 GFD (25 LMH). Larger plants use multiple units or a multi-cell tank, confirmed per project. Units are assembled in Poughkeepsie, NY.

Try it first: the Scrub-UF80 ships as a unit to buy or rent for a pilot on your own water. Rentals

Honest selection

What UF will and won’t do here.

Scrub UF is a filtration step, not biological treatment. For BOD and nitrogen removal start with an MBR (Swing or Palisade). Reuse approvals are state-specific, and no state reuse approval is claimed on this page. We review the requirements with you per project.

What to send

Water first.

  • Plant flow, average and peak
  • Clarifier effluent TSS, turbidity, TP
  • Reuse or discharge permit limits
  • Existing tankage and filter footprint
  • Disinfection and any RO downstream

Quick quote · 1 minute

Send us the stream.

Only your name and email are required. We reply from tom@zyramic.com, usually within one business day. Or call 845-402-6318.

Call 845-402-6318

Related

UF for industrial water reuse · UF for RO pretreatment · Scrub UF product page

We presently have a manufacturing facility in Poughkeepsie, New York, and the ability to ship from Europe and Asia.

Warranty against defects in materials and workmanship. For industrial applications, membrane life depends on the service duty, so we run a pilot test to establish expected system life.

Tell us your domestic-content requirements, including Build America, Buy America (BABA), and we'll review what we can document.