Home / Applications / Surface and drinking water

Surface water · Drinking water · Submerged UF

UF for surface and drinking water.

A physical UF barrier for surface, spring and groundwater that handles turbid raw water, often without a flocculant. Scrub UF can replace a floc, settle and sand-filter train with a screen, UF and disinfection.

Small Scrub UF packaged unit on spring water
0.04 µmnominal PES pore size
< 0.3 NTUpermeate in one spring-water case from 11–40 NTU raw
Often noneflocculant on direct surface-water filtration
9–12 GFDdesign flux (15–20 LMH); may run higher on clean water

Typical values from reference installations, test data and design studies. Your proposal sets the design point and guaranteed values for your feed.

Process

Screen, UF, disinfect.

Surface water or groundwater→Fine screen→Scrub UF→Disinfection→Potable water
ItemScrub UFConventional treatment
Process stepsScreen, UF, disinfectionCoagulation, flocculation, settling, sand filter, disinfection
CoagulantOften noneRequired; dose tracks raw water
Turbidity swingsTolerated by the membrane barrierNeed dose re-tuning
SludgeLess, without coagulant chemicalsChemical sludge
FootprintCompact processLarge settling and filter area

Treatment for potable use must meet the applicable state and federal requirements. We review certification and approval needs with you per project.

Reference case

Village spring water.

ItemResult
CapacityAbout 26,000 gpd (100 m³/d)
SourceSurface mountain spring water
Raw turbidity11–40 NTU
Permeate turbidityBelow 0.3 NTU
UseDaily household water after disinfection

One reference case. Results on other sources will differ.

Flux and transmembrane pressure from one long-term river-water test
One long-term river-water test. Observed flux is not the design flux. Proposals use 9–12 GFD (15–20 LMH) unless a pilot supports more.

What the long-term test shows.

ItemValueNote
FeedMicro-polluted river waterOne test site
Observed fluxAbout 24–29 GFD (40–50 LMH)Clean surface water; not a design value
Observed TMPAbout 1.1–2.3 psi (7–16 kPa)Recovers after each cleaning cycle and drain
Zyramic design flux9–12 GFD (15–20 LMH); peak 15 GFD (25 LMH)Basis for proposals until pilot data supports more

Compared with submerged hollow fiber.

One reference comparisonScrub UFSubmerged hollow fiber
Feed TSS toleranceAbout 200 mg/LAbout 100 mg/L
Time between chemical cleansAbout 20 daysAbout 7 days
Membrane lifeAbout 5 yearsAbout 3 years
Water recoveryAbout 90%About 85%

Typical reference values from published test data. Feed-dependent; we confirm by pilot.

Packaged units

Scrub UF sizes, 861 to 11,300 ft² (80 to 1,050 m²).

ModelMembrane areaL × W × HDesign permeate*
Scrub-UF80861 ft² (80 m²)3'-3" × 3'-3" × 5'-11"
(1,000 × 1,000 × 1,800 mm)
5–7 gpm
7,800–10,300 gpd (29–38 m³/d)
Scrub-UF260-12,800 ft² (260 m²)3'-11" × 7'-3" × 7'-5"
(1,200 × 2,200 × 2,250 mm)
17–23 gpm
25,200–33,600 gpd (94–125 m³/d)
Scrub-UF350-13,770 ft² (350 m²)3'-11" × 7'-3" × 8'-4"
(1,200 × 2,200 × 2,530 mm)
24–31 gpm
33,900–45,200 gpd (126–168 m³/d)
Scrub-UF260-25,600 ft² (520 m²)7'-7" × 7'-3" × 7'-5"
(2,300 × 2,200 × 2,250 mm)
35–47 gpm
50,400–67,200 gpd (187–250 m³/d)
Scrub-UF350-311,300 ft² (1,050 m²)11'-0" × 7'-3" × 8'-4"
(3,350 × 2,200 × 2,530 mm)
71–94 gpm
101,700–135,600 gpd (378–504 m³/d)

*Design permeate at 9–12 GFD (15–20 LMH), peak 15 GFD (25 LMH). On clean water, flux may run higher; we confirm that by pilot or reference data before we design to it. A 0.16 in (4.0 mm) sheet family is also available (Scrub-UF210 / UF280).

Permeate by model at design flux 9 to 12 GFD, with a higher clean-water guidance band
Design permeate at 9–12 GFD (15–20 LMH). The upper band is clean-water guidance and may run higher. It is not the design point.

Larger plants can use a multi-cell tank, with each cell taken offline for cleaning while the others keep producing. We confirm the configuration per project. Units are assembled in Poughkeepsie, NY. Tell us your domestic-content or BABA requirements and we'll review what we can document. UF catalog Rev03 (PDF).

Questions

Common questions

Can Scrub UF run without flocculant on surface water?

In many cases, yes. Direct filtration of surface water without flocculant is a common Scrub UF duty. Very high color or organics may still need a dose or a polishing step.

Is Scrub UF certified for drinking water?

Certification and state approval requirements depend on the project. Tell us your requirements and we will review what we can document.

How fast can I pilot?

The Scrub-UF80 packaged unit, 861 ft² (80 m²), is available to buy or rent for a pilot.

What flux do you design to?

9–12 GFD (15–20 LMH). Clean surface water may run higher; we confirm that by pilot before designing to it.

Send us your water data.

We will size Scrub UF for your flow and feed, or set up a Scrub-UF80 pilot.